Environmental | Operating temperature: -20°C~70°C, derated for use above 55°C (can be started at -40°C)
Storage temperature: -40°C~80°C
Relative humidity: ≤95%RH, no condensation
Cooling method: Forced air cooling
Altitude: ≤2000m, derated for use above 2000m
Atmospheric pressure: 79kPa~106kPa
IP protection class: IP20 |
---|
AC input | Input format:
Single phase L+N+PE (90-305Vac)
Dual phase three wire L+L+PE (110Vac)
Voltage range: 90Vac~305Vac
Maximum static voltage when not working: 315Vac
Rated voltage: 220/277Vac
Maximum current 36A
Grid frequency: 45Hz~65Hz
Rated frequency: 50Hz/60Hz
Standby power consumption:<6W standard standby mode |
---|
DC output | Voltage range: 150Vdc~1000Vdc (max output 20A at 50~150Vdc, but no performance requirement)
Current range: 0~20A (current limiting point can be set)
Rated current: 7A (need to set current limiting point)
Voltage regulation accuracy: <±0.5%
Current regulation accuracy: ≤±1% (output load 20% rated current ~ max output current)
Load regulation rate: ≤±0.5%
Grid regulation rate: ≤±0.1% (test range is 220Vac~277Vac)
Startup overshoot: ≤±2%
Voltage ripple coefficient: ≤1% & ≤5V (150Vdc~1000Vdc, 0~20MHz) |
---|
Power factor and THD | Power factor:
≥0.95 @25%~50% full load output power
≥0.98 @50%~100% full load output power
≥0.99 @100% full load output power, nominal input voltage and frequency
THD: ≤5% @50%~100% full load output power |
---|
Peak efficiency | Peak efficiency 95.7% @750V-6A, rated input voltage |
---|
Full load efficiency | Typical full load efficiency 95.3%; minimal full load efficiency ≥95.0%@1000V-7A, rated input voltage |
---|
EMC | Conducted emission: Class B, IEC61851-21-2:2021 compliant
Radiated emission: Class B, IEC61851-21-2:2021 complian |
---|
Certification | TUV CE: IEC61851-1:2023; IEC61851-23:2023; EN61851-1:2019; EN61851-23:2014
cTUVus: UL2202, CSA C22.2 No.346:22 |
---|
Others | Power-on instantaneous surge current: < Max steady-state peak current * 110%
Noise: Standard mode with max 75dB, de-noise mode with max 65dB, silent mode with max 55dB
Startup time: Time delay from AC power-on to module output ≤ 8s
Grounding resistance: Grounding resistance ≤0.1Ω, should be able to withstand current ≥25A
Lightning protection: 5kA
Leakage current: ≤3.5mA, @230Vac/50Hz
Insulation resistance: Insulation resistance between DC part, AC part to enclosure, and AC part to DC part ≥10MΩ
Insulation strength
Apply DC voltage between the two, test for 1 minute, no breakdown, no flashover, and a steady-state leakage current of less than 1mA.
Between the AC input terminal and CAN: 4242Vdc
Between the AC input terminal and the enclosure: 4242Vdc
Between the AC input terminal and DC output terminal: 4242Vdc
Between the DC output terminal and the enclosure: 4242Vdc
Between the DC output terminal and CAN: 4242Vdc
Between CAN and the enclosure: 707Vdc
REACH: REACH 241
RoHS: R10 |
---|
Mechnical | Dimensions: 87±1mm (height) ×177.5±1mm (width) ×385±1mm (depth)
Weight: ≤7.2kg |
---|